Hall Effect Current Sensor

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Beijing

  • Validity to:

    Long-term effective

  • Last update:

    2021-03-19 01:51

  • Browse the number:

    320

Send an inquiries

Company Profile

Acrel Co., Ltd

By certification [File Integrity]

Contact:ankerui2021(Mr.)  

Email:

Telephone:

Phone:

Area:Beijing

Address:Beijing

Website:http://www.acrel-global.com/ http://ankerui2021.yshfsteeltube.com/

Product details

1.Hall sensor

Hall current sensors are mainly used to isolate and convert AC, DC, pulse and other complex signals. After signacontrol of current signalsls are converted according to the Hall Effect Theory, they can be directly acquired by AD, DSP, PLC, secondary instruments and other devices. Hall current sensors are widely applicable for acquisition and feedback in the current monitoring, battery application, inverter, solar power management, direct current cabinet, DC motor drive, electroplating, welding, frequency converter, UPS servo control systems. They feature the quick response, wide range of measurement, high precision, strong overload capacity, good linearity and excellent anti-interference performance.


1.1Open-loop Hall current sensor

1.1.1Explanation for type

1.1.2Technical data

Technical parameters

Data

Split/closed open-loop

Hall (true RMS)

Output

Nominal value

Voltage: ±5V/±4V

Current: 4-20mA

Zero offset voltage (current)

Voltage: ±20mV

Current:±0.05mA

Offset voltage (current) drift

Voltage: ≤±1.0mV/℃

Current:±0.04mA/ ℃

Linearity

≤0.2%FS

Power voltage

DC±15V

DC 24V

Bandwidth

0-20kHz


Response time

≤5us

≤1ms

Dielectric strength

Permissible 2500VAC between input/ output and power supply at the power frequency

Accuracy class

1.0

Ambient conditions

Temperature

Operating temperature:-25℃-+70℃; storage temperature: -40℃-+85℃

Humidity

≤95%RH, no dew, no aggressive gas

Altitude

≤3500m


1.1.3 Split open-loop hall current sensor

Fig.1 Fig.2


1.1.3.1Spec. and size (unit:mm)

Size Specification

Outline size

Through size

Mounting size

Figure

W

H

D

a

e

Φ

M

N

AHKC-EKA

60

64

16

/

/

20

47

/

Fig.1

AHKC-EKAA

60

64

16

/

/

20

47

/

Fig.1

AHKC-EKDA

60

64

16

/

/

20

47

/

Fig.1

AHKC-EKB

100

102

24

/

/

40

80

/

Fig.1

AHKC-EKBA

100

102

24

/

/

40

80

/

Fig.1

AHKC-

EKBDA

100

102

24

/

/

40

80

/

Fig.1

AHKC-K

127

63

25

64

16

/

/

30

Fig.2

AHKC-KAA

127

63

25

64

16

/

/

30

Fig.2

AHKC-KDA

127

63

25

64

16

/

/

30

Fig.2

AHKC-H

149

79

25

82

32

/

/

46

Fig.2

AHKC-KA

176

95.5

29

104

36

/

/

60

Fig.2

AHKC-HB

204

111.5

29

132

52

/

/

48 ×

2

Fig.2

 Specification

 Rated current

Power supply

Rated output

Measuring aperture  (mm)

Precision degree

AHKC-EKA

0~(20-500)A

±15V

5V

φ 20

1

AHKC-     EKAA

DC 0~(50-500)A

12V/24V

4~20mA

φ 20

1

AHKC- EKDA

AC 0~(50-500)A

12V/24V

4~20mA

φ 20

1

AHKC-EKB

0~(200-1000)A

±15V

5V

φ 40

1

AHKC- EKBA

DC 0~(200- 1000)A

12V/24V

4~20mA

φ 40

1

Note: Rated current unlabeled indicates  that AC and DC input current can be measured,  please specify when ordering.


1.1.3.2Cross-reference tables of spec. -parameter

AHKC- EKBDA

AC 0~(200~ 1000)A

12V/24V

4~20mA

φ 40

1

AHKC-K

0~(400-2000)A

±15V

5V

64×16

1

AHKC- KAA

DC 0~(400- 2000)A

12V/24V

4~20mA

64×16

1

AHKC- KDA

AC 0~(400- 2000)A

12V/24V

4~20mA

64×16

1

AHKC-H

0~(500-3000)A

±15V

5V

82×32

1

AHKC-KA

0~(500-5000)A

±15V

5V

104×36

1

AHKC-HB

0~(2000-20000)A

±15V

5V

132×52

1

Note: Rated current unlabeled indicates  that AC and DC input current can be measured,  please specify when ordering.

 

1.1.4  Closed hall current sensor

1.1.4.1 Spec. and size (unitmm)

Fig.1

Fig.2

Size Specification

Outline size(mm)

Through size(mm)

Mounting

       size(mm)

Figure

W

H

D

a

e

Φ

M

N

AHKC-E

53

72

16

/

/

21

47

/

Fig.1

AHKC-LT

90

73.5

25

/

/

32.5

74.5

71

Fig.1

AHKC-BS

43

32.5

19

20.5

10.5

/

/

/

Fig.2

AHKC-BSA

43

32.5

19

20.5

10.5

/

/

/

Fig.2

AHKC-F

74

57

22

43

13

/

/

22

Fig.2

AHKC-FA

94

60.5

26.5

52

15

/

83

28

Fig.2

AHKC-HAT

94

76.5

24

52.5

32

/

83

28

Fig.2


1.1.4.2 Cross-reference tables  of spec. -parameter

 Specification

 Rated current

Power supply

Rated output

Measuring aperture (mm)

Precisio n degree

AHKC-E

0~(20-500)A

±15V

5V

φ 20

1

AHKC-LT

0~(100-800)A

±15V

5V

φ 32.5

1

AHKC-BS

0~(20-500)A

±15V

5V

20.5*10.5

1

AHKC-BSA

DC 0~(50-500)A

12V/15V/24 V

4~20mA

20.5*10.5

1

AHKC-F

0~(200-1000)A

±15V

5V

43*13

1

AHKC-FA

0~(200-1500)A

±15V

5V

52*15

1

AHKC-HAT

0~(400-2000)A

±15V

5V

52*32

1

Note: Rated current unlabeled indicates that AC and DC input current can be measured, please specify when ordering.





 2.Closed hall current sensor

Closed-loop Hall current sensor is also called Hall magnetic balancing current sensor. It incorporates the mentioned theory with magnetic balancing theory. In other words, the ferromagnetic field concentrator concentrates the magnetic field generated by primary current and applies it to the Hall component. Then the voltage signal output from Hall component is amplified and becomes the input of power amplifier. The offset current output flows through the secondary compensating coil. The magnetic field generated by secondary coil is opposite to the field generated by primary current. In such way, the primary field is compensated and the Hall output is reduced gradually. When the primary field is equivalent to the secondary one and the offset current keeps stable, it is the magnetic balancing.This circuit mainly consists of electromagnetism conversion component, circuit amplifier and drive compensating circuit.



2.1  Explanation for type

http://www.acrel-global.com/